Commit 9c62e22
hwmon: (gsc-hwmon) fix fan pwm setpoint show functions
The Linux hwmon sysfs API values for pwmX_auto_pointY_pwm represent an
integer value between 0 (0%) to 255 (100%) and the pwmX_auto_pointY_temp
represent millidegrees Celcius.
Commit a6d80df ("hwmon: (gsc-hwmon) fix fan pwm temperature
scaling") properly addressed the incorrect scaling in the
pwm_auto_point_temp_store implementation but erroneously scaled
the pwm_auto_point_pwm_show (pwm value) instead of the
pwm_auto_point_temp_show (temp value) resulting in:
# cat /sys/class/hwmon/hwmon0/pwm1_auto_point6_pwm
25500
# cat /sys/class/hwmon/hwmon0/pwm1_auto_point6_temp
4500
Fix the scaling of these attributes:
# cat /sys/class/hwmon/hwmon0/pwm1_auto_point6_pwm
255
# cat /sys/class/hwmon/hwmon0/pwm1_auto_point6_temp
45000
Fixes: a6d80df ("hwmon: (gsc-hwmon) fix fan pwm temperature scaling")
Cc: stable@vger.kernel.org
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Link: https://lore.kernel.org/r/20250718200259.1840792-1-tharvey@gateworks.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>1 parent 89be9a8 commit 9c62e22
1 file changed
Lines changed: 2 additions & 2 deletions
| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
64 | 64 | | |
65 | 65 | | |
66 | 66 | | |
67 | | - | |
| 67 | + | |
68 | 68 | | |
69 | 69 | | |
70 | 70 | | |
| |||
99 | 99 | | |
100 | 100 | | |
101 | 101 | | |
102 | | - | |
| 102 | + | |
103 | 103 | | |
104 | 104 | | |
105 | 105 | | |
| |||
0 commit comments