Commit 0bb619f
thermal/intel/intel_soc_dts_iosf: Fix reporting wrong temperatures
Since commit 955fb87 ("thermal/intel/intel_soc_dts_iosf: Use Intel
TCC library") intel_soc_dts_iosf is reporting the wrong temperature.
The driver expects tj_max to be in milli-degrees-celcius but after
the switch to the TCC library this is now in degrees celcius so
instead of e.g. 90000 it is set to 90 causing a temperature 45
degrees below tj_max to be reported as -44910 milli-degrees
instead of as 45000 milli-degrees.
Fix this by adding back the lost factor of 1000.
Fixes: 955fb87 ("thermal/intel/intel_soc_dts_iosf: Use Intel TCC library")
Reported-by: Bernhard Krug <b.krug@elektronenpumpe.de>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Cc: 6.3+ <stable@vger.kernel.org> # 6.3+
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>1 parent 858fd16 commit 0bb619f
1 file changed
Lines changed: 1 addition & 1 deletion
| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
398 | 398 | | |
399 | 399 | | |
400 | 400 | | |
401 | | - | |
| 401 | + | |
402 | 402 | | |
403 | 403 | | |
404 | 404 | | |
| |||
0 commit comments