clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll
The set rate and determine rate operations are different between Stromer and Stromer Plus PLLs. Since the programming sequence is different, the PLLs dont get configured properly and random, inexplicable crash/freeze is seen. Hence, use stromer plus ops for ipq_pll_stromer_plus. Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> Acked-by: Stephen Boyd <sboyd@kernel.org> Fixes: c7ef7fb ("clk: qcom: apss-ipq-pll: add support for IPQ5332") Signed-off-by: Kathiravan T <quic_kathirav@quicinc.com> Signed-off-by: Varadarajan Narayanan <quic_varada@quicinc.com> Link: https://lore.kernel.org/r/c86ecaa23dc4f39650bcf4a3bd54a617a932e4fd.1697781921.git.quic_varada@quicinc.com Signed-off-by: Bjorn Andersson <andersson@kernel.org>
1 parent 84da489 commit 267e291

1 file changed

Lines changed: 1 addition & 1 deletion

File tree

drivers/clk/qcom/apss-ipq-pll.c

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
6868
.fw_name = "xo",
6969
},
7070
.num_parents = 1,
71-
.ops = &clk_alpha_pll_stromer_ops,
71+
.ops = &clk_alpha_pll_stromer_plus_ops,