Commit 62dd96a
iio: adc: ad4000: fix reading unsigned data
Fix reading unsigned data from the AD4000 ADC via the _raw sysfs
attribute by ensuring that *val is set before returning from
ad4000_single_conversion(). This was not being set in any code path
and was causing the attribute to return a random value.
Fixes: 938fd56 ("iio: adc: Add support for AD4000")
Signed-off-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/20241030-iio-adc-ad4000-fix-reading-unsigned-data-v1-1-2e28dd75fe29@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>1 parent c174b53 commit 62dd96a
1 file changed
Lines changed: 2 additions & 0 deletions
| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
344 | 344 | | |
345 | 345 | | |
346 | 346 | | |
| 347 | + | |
| 348 | + | |
347 | 349 | | |
348 | 350 | | |
349 | 351 | | |
| |||
0 commit comments