| 1 | +# SPDX-License-Identifier: (GPL-2.0-only or BSD-2-Clause) |
| 2 | +# Copyright (C) 2020 Texas Instruments Incorporated |
| 3 | +%YAML 1.2 |
| 4 | +--- |
| 5 | +$id: "http://devicetree.org/schemas/power/supply/bq256xx.yaml#" |
| 6 | +$schema: "http://devicetree.org/meta-schemas/core.yaml#" |
| 7 | + |
| 8 | +title: TI bq256xx Switch Mode Buck Charger |
| 9 | + |
| 10 | +maintainers: |
| 11 | + - Ricardo Rivera-Matos <r-rivera-matos@ti.com> |
| 12 | + |
| 13 | +description: | |
| 14 | + The bq256xx devices are a family of highly-integrated battery charge |
| 15 | + management and system power management ICs for single cell Li-ion and Li- |
| 16 | + polymer batteries. |
| 17 | +
|
| 18 | + Datasheets: |
| 19 | + - https://www.ti.com/lit/ds/symlink/bq25600.pdf |
| 20 | + - https://www.ti.com/lit/ds/symlink/bq25601.pdf |
| 21 | + - https://www.ti.com/lit/ds/symlink/bq25600d.pdf |
| 22 | + - https://www.ti.com/lit/ds/symlink/bq25601d.pdf |
| 23 | + - https://www.ti.com/lit/ds/symlink/bq25611d.pdf |
| 24 | + - https://www.ti.com/lit/ds/symlink/bq25618.pdf |
| 25 | + - https://www.ti.com/lit/ds/symlink/bq25619.pdf |
| 26 | +
|
| 27 | +properties: |
| 28 | + compatible: |
| 29 | + enum: |
| 30 | + - ti,bq25600 |
| 31 | + - ti,bq25601 |
| 32 | + - ti,bq25600d |
| 33 | + - ti,bq25601d |
| 34 | + - ti,bq25611d |
| 35 | + - ti,bq25618 |
| 36 | + - ti,bq25619 |
| 37 | + |
| 38 | + reg: |
| 39 | + maxItems: 1 |
| 40 | + |
| 41 | + ti,watchdog-timeout-ms: |
| 42 | + $ref: /schemas/types.yaml#/definitions/uint32 |
| 43 | + default: 0 |
| 44 | + description: | |
| 45 | + Watchdog timer in ms. 0 (default) disables the watchdog |
| 46 | + minimum: 0 |
| 47 | + maximum: 160000 |
| 48 | + enum: [ 0, 40000, 80000, 160000] |
| 49 | + |
| 50 | + input-voltage-limit-microvolt: |
| 51 | + description: | |
| 52 | + Minimum input voltage limit in µV with a 100000 µV step |
| 53 | + minimum: 3900000 |
| 54 | + maximum: 5400000 |
| 55 | + |
| 56 | + input-current-limit-microamp: |
| 57 | + description: | |
| 58 | + Maximum input current limit in µA with a 100000 µA step |
| 59 | + minimum: 100000 |
| 60 | + maximum: 3200000 |
| 61 | + |
| 62 | + monitored-battery: |
| 63 | + $ref: /schemas/types.yaml#/definitions/phandle |
| 64 | + description: phandle to the battery node being monitored |
| 65 | + |
| 66 | + interrupts: |
| 67 | + maxItems: 1 |
| 68 | + description: | |
| 69 | + Interrupt sends an active low, 256 μs pulse to host to report the charger |
| 70 | + device status and faults. |
| 71 | +
|
| 72 | +required: |
| 73 | + - compatible |
| 74 | + - reg |
| 75 | + - monitored-battery |
| 76 | + |
| 77 | +additionalProperties: false |
| 78 | + |
| 79 | +examples: |
| 80 | + - | |
| 81 | + bat: battery { |
| 82 | + compatible = "simple-battery"; |
| 83 | + constant-charge-current-max-microamp = <2040000>; |
| 84 | + constant-charge-voltage-max-microvolt = <4352000>; |
| 85 | + precharge-current-microamp = <180000>; |
| 86 | + charge-term-current-microamp = <180000>; |
| 87 | + }; |
| 88 | + #include <dt-bindings/gpio/gpio.h> |
| 89 | + #include <dt-bindings/interrupt-controller/irq.h> |
| 90 | + i2c { |
| 91 | +
|
| 92 | + clock-frequency = <400000>; |
| 93 | +
|
| 94 | + #address-cells = <1>; |
| 95 | + #size-cells = <0>; |
| 96 | +
|
| 97 | + charger@6b { |
| 98 | + compatible = "ti,bq25601"; |
| 99 | + reg = <0x6b>; |
| 100 | + monitored-battery = <&bat>; |
| 101 | +
|
| 102 | + interrupt-parent = <&gpio1>; |
| 103 | + interrupts = <16 IRQ_TYPE_EDGE_FALLING>; |
| 104 | + ti,watchdog-timeout-ms = <40000>; |
| 105 | +
|
| 106 | + input-voltage-limit-microvolt = <4500000>; |
| 107 | + input-current-limit-microamp = <2400000>; |
| 108 | + }; |
| 109 | + }; |
| 110 | +... |