Commit f5728a4
ice: Fix PF with enabled XDP going no-carrier after reset
Commit 6624e78 ("ice: split ice_vsi_setup into smaller
functions") has refactored a bunch of code involved in PFR. In this
process, TC queue number adjustment for XDP was lost. Bring it back.
Lack of such adjustment causes interface to go into no-carrier after a
reset, if XDP program is attached, with the following message:
ice 0000:b1:00.0: Failed to set LAN Tx queue context, error: -22
ice 0000:b1:00.0 ens801f0np0: Failed to open VSI 0x0006 on switch 0x0001
ice 0000:b1:00.0: enable VSI failed, err -22, VSI index 0, type ICE_VSI_PF
ice 0000:b1:00.0: PF VSI rebuild failed: -22
ice 0000:b1:00.0: Rebuild failed, unload and reload driver
Fixes: 6624e78 ("ice: split ice_vsi_setup into smaller functions")
Reviewed-by: Przemek Kitszel <przemyslaw.kitszel@intel.com>
Signed-off-by: Larysa Zaremba <larysa.zaremba@intel.com>
Reviewed-by: Simon Horman <horms@kernel.org>
Tested-by: Chandan Kumar Rout <chandanx.rout@intel.com> (A Contingent Worker at Intel)
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>1 parent 4d50fcd commit f5728a4
1 file changed
Lines changed: 3 additions & 0 deletions
| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
2371 | 2371 | | |
2372 | 2372 | | |
2373 | 2373 | | |
| 2374 | + | |
| 2375 | + | |
| 2376 | + | |
2374 | 2377 | | |
2375 | 2378 | | |
2376 | 2379 | | |
| |||
0 commit comments