Validate enclosure, BT Audio, and temperature-role transitions on hardware #70
Relevant excerpt, lightly grammar-corrected for publication. Credentials, personal data, private paths, and unrelated transcript content are omitted.
Verify door and BT Audio transitions, smooth informational LED changes, keep warning states immediate, and validate the temperature roles on real hardware.
Original request (lightly corrected): Learn the different BT Audio status indicator LED types/modes and make it active HIGH, unlike the active-LOW inputs.
Hardware acceptance must now include: record the BT Audio indicator's observed modes and polarity, prove active-HIGH drive without disturbing input interpretation, and attach board-specific evidence. Pair this with the commissioning fallback where automatic identification is inconclusive.
✅ Firmware/host protocol paths publish typed board events to UI, IPC, and scripting surfaces.
⚠️ The connected board still needs a live proof that reed open/close reaches TUI, scripting, and IPC immediately, and that illumination raises T1 while T2 remains comparatively cool.
⚠️ Capture final-image identity, timestamps, and before/after observations during this pass.
Final board 37D3BC5C currently reports door open, T1 32.54 C and T2 27.90 C, with the intended thermal separation. Typed events and WS/Socket.IO transport passed synthetic/protocol acceptance, but no physical close/reopen occurred during this checkpoint. Instant propagation to Web/TUI/CLI/script remains a human gate; keep this issue open.
Activity
atomicdeploy commentedon Aug 11, 2026
Hardware acceptance must now include: record the BT Audio indicator's observed modes and polarity, prove active-HIGH drive without disturbing input interpretation, and attach board-specific evidence. Pair this with the commissioning fallback where automatic identification is inconclusive.
atomicdeploy commentedon Aug 12, 2026
2026-08-12 reconciliation: immediate door/thermal event check
atomicdeploy commentedon Aug 13, 2026
Final board
37D3BC5Ccurrently reports door open, T1 32.54 C and T2 27.90 C, with the intended thermal separation. Typed events and WS/Socket.IO transport passed synthetic/protocol acceptance, but no physical close/reopen occurred during this checkpoint. Instant propagation to Web/TUI/CLI/script remains a human gate; keep this issue open.