dockwarden is a safety-first command-line tool for Dell docking stations on macOS and Linux. The current target is the Dell Dock WD19.

Safety notice: Firmware updates can leave a dock unusable if power or USB-C connectivity is lost. Review the read-only plan first. Keep the dock on stable power. Never run an unattended firmware update.

CI License: MIT

Contents

Install

The simplest installation uses the published release checksums and the bootstrap installer. It detects macOS or Linux and the host architecture, downloads the matching archive, verifies its SHA-256, and installs the binary for the current user.

curl -fsSL https://github.com/fexxdev/dockwarden/releases/latest/download/install.sh | sh

The installer places dockwarden in $HOME/.local/bin. Add that directory to PATH if it is not already present. On macOS, the installer also installs the complete managed fwupdtool runtime and checks the required Homebrew formulae. If Homebrew is not installed, the installer prints the exact prerequisite command and stops. It never writes firmware.

To install a specific release, pin the tag:

curl -fsSL https://github.com/fexxdev/dockwarden/releases/latest/download/install.sh \
  | DOCKWARDEN_VERSION=v0.3.0 sh

To install an archive that you downloaded manually:

mkdir dockwarden-v0.3.0-darwin-arm64
tar -xzf dockwarden-v0.3.0-darwin-arm64.tar.gz \
  -C dockwarden-v0.3.0-darwin-arm64
cd dockwarden-v0.3.0-darwin-arm64
./install.sh

Release v0.3.0 provides archives for macOS arm64, macOS amd64, Linux amd64, and Linux arm64, plus the SHA256SUMS file. Each archive contains the binary, installer, README, changelog, and license. The macOS archives also contain the managed fwupd-2.2.1 prefix. Keep that complete prefix. Do not copy only its fwupdtool executable.

On macOS, the installer runs a read-only fwupd HID permission check. If macOS denies access, it prints the exact path to the Input Monitoring setting. Open System Settings > Privacy & Security > Input Monitoring. Enable the terminal or app that runs dockwarden, then quit and reopen that terminal or app. The same check is available with dockwarden doctor.

On Linux, the installer installs the fwupd package when fwupdmgr is missing. It supports apt-get, dnf, yum, pacman, and zypper. The installer can ask for sudo. Dockwarden itself never invokes sudo.

Run these commands first. They are read-only:

dockwarden --version
dockwarden status
dockwarden doctor
dockwarden update

dockwarden update shows the plan and does not download or write firmware. Only dockwarden update --apply can start an update. Use it only with the dock connected, stable power, an attended computer, and an explicit decision to proceed.

Does it work?

Yes. The verified WD19 development run updated the dock. The update command itself returned an error during progress, so the final result was accepted only after a physical reconnect and a fresh read-only status check.

The observed versions were:

Component Before After Result
Package 01.00.47.01 01.01.01.01 Updated
Embedded controller 01.01.00.13 01.01.00.15 Updated
USB hub Gen1 01.23 01.23 Already current
USB hub Gen2 01.62 01.62 Already current
MST 05.07.08 05.07.08 Already current

The install used the official Dell CAB DellDockFirmwarePackage_WD19_WD22_HD22_WD25_SD25_01.01.11.cab. Dockwarden verified its SHA-256 before handing it to upstream fwupdtool.

The relevant output stopped at:

Writing…: 70.5%
fwupdtool: exit status 1

The old logger retained only the first 4096 bytes, so the final low-level error is not available. The output contains several device restart and wait phases. This is consistent with a transient HID or USB re-enumeration loss, but it does not prove the cause. fwupd also printed a package validation warning. The log does not prove that warning caused the interruption.

After the recovery reconnect, status reported the new package and embedded controller versions, no checks, and no warnings. This confirms the effective hardware result even though the original process did not exit cleanly.

The local evidence is preserved in dockwarden-flash-20260805-0005.txt and dockwarden-recovery-status-20260805.txt. New logs preserve both the start and the end of command output. Dockwarden performs one install attempt only. It does not retry an install after an error; it performs a read-only verification instead.

Recovery

Use this section after an interrupted or failed update. Keep the dock on its AC adapter. Prevent the computer from sleeping. Do not start a second flash until dockwarden status proves the result of the first attempt.

First save a complete log and run the read-only checks:

dockwarden --log-file "$HOME/dockwarden-recovery.txt" status
dockwarden --log-file "$HOME/dockwarden-recovery.txt" doctor

The following table covers every state that Dockwarden can verify:

Observed state Safe action Do not do
up_to_date after reconnect Keep the dock connected. Save the log. The candidate is not newer than the verified dock firmware. Do not flash again to test the result.
update_failed before any write Keep the dock connected. Read the reason. Fix the listed preflight, permission, package, or link problem. Run status again. Do not force the update or use a different package.
version_check_unavailable Stop. Keep the dock powered. Save the report and restore a readable USB/HID connection before any apply. Do not treat missing versions as an update.
update_staged or update-pending Wait for the process to exit. Disconnect the USB-C cable once. Wait ten seconds. Reconnect it. Run status. Do not run update --apply again before this check.
Error during progress, such as Writing…: 70.5% If progress is active, wait for the process to exit. After it exits, reconnect the USB-C cable once and run status. A new package and controller version confirms the write. Do not unplug a dock while the writer is still active. Do not repeat the flash from the error message alone.
update_verified The candidate versions match the dock. Keep the log. No recovery action is needed. Do not flash again.
Mixed component versions Stop. Save the log and the pre/post version report. Do not force another package. Use Dell recovery support. Do not downgrade or skip component checks.
No dock in status after reconnect Remove downstream USB devices. Disconnect the host cable. Remove dock power for 30 seconds. Reconnect power first, then the host cable. Run status and doctor. Do not run raw fwupdtool install commands.
Dock has no LEDs or never enumerates Repeat the power-first cycle once with another USB-C port and cable. If the dock still does not enumerate, stop software attempts. Use Dell service or a Dell recovery utility on a supported Windows system, when Dell lists one for the model. Do not open the dock or apply an unverified image.
Computer, cable, or power failed during the write Restore stable power. Use the power-first cycle. Run status. Treat missing or mixed versions as an unresolved failure. Do not assume that a completed progress bar means that every component is valid.
Same failure repeats Keep all logs and stop. Report the model, serial, versions, state, and exact error to Dell support. Do not retry without new evidence.

If the dock enumerates and all candidate versions match, the firmware write was effective even if the writer returned an error. If the dock reports a pending state, reconnect once and verify again. If the dock does not enumerate, the software cannot guarantee recovery. Dell service or the official Dell recovery path is required.

Never use a raw fwupdtool install command, a forced downgrade, or a CAB from an unknown source. Keep the recovery log because it can contain dock identifiers.

Dell resources

These are official Dell links for the WD19. Dell can redirect a page to your region. The product page is the source of truth when a direct file link changes.

Downloads

The CAB and BIN are Dell files. Dockwarden uses the verified CAB through its fwupd backend. Do not run either file directly or mix files from different releases. The Windows utilities are reference and recovery links only; Dockwarden never executes a Dell .exe. Check the checksum on the Dell driver page before use.

Recovery and troubleshooting

Use Dell's power-cycle procedure when the dock has no power or does not enumerate. Use Dockwarden's recovery table first. It records the result before you consider another update.

Manuals and technical documentation

The Administrator's Guide documents the Dell update states, component version checks, logs, error handling, and post-update reconnect. It is the best Dell reference for service and recovery work.

What it does

Dockwarden can:

  • identify the WD19 USB device and its topology;
  • report USB, Ethernet, audio, and downstream USB services;
  • read component firmware versions through the upstream fwupd Dell plugin on macOS;
  • check official Dell firmware metadata and the pinned CAB checksum;
  • create a read-only update plan;
  • update the WD19 through fwupdmgr on Linux;
  • update the WD19 through the upstream standalone fwupdtool on macOS.

The macOS inventory and writer use the upstream Dell Dock plugin from the fwupd Darwin branch. That plugin owns the Apple HID transport and the Dell protocol. Dockwarden selects one exact WD19 DeviceId from JSON, compares the USB serial, and verifies every candidate component after the install.

Some WD19 units expose the Gen1 hub as USB 413c:b06f without a HID serial. macOS can still report its exact USB location, such as 00135000, and its USB descriptor version. Dockwarden shows this as physical read-only evidence. It never treats that descriptor as firmware evidence and never uses it to permit a write. The state remains version_check_unavailable until fwupd reads the Gen1 endpoint directly.

Dockwarden does not execute Dell Windows .exe packages. It does not accept arbitrary payloads, forced downgrades, or unverified firmware files. A USB descriptor version is not a firmware version.

Safety model

Before an install, macOS checks the dock identity, one fwupd target, update state, and all five component versions from a read-only JSON inventory. It selects a single dell_dock DeviceId by plugin, embedded-controller instance ID, and the USB serial prefix. The upstream Dell plugin owns the hardware checks and write protocol. Any failed check stops the install.

The macOS permission probe is also fail-closed. A missing HID/Input Monitoring permission can report status, but it blocks update --apply until you enable the permission and restart the terminal or app.

An update_staged result means that the platform accepted the update and requires a physical reconnect. Reconnect the dock USB-C cable, then run dockwarden status. An update_verified result means that fwupd returned success, or returned an error after the dock reported every candidate version. If verification is not possible, the result remains update_failed or update_staged.

Every command writes user-only text logs to dockwarden-log.txt. Use --log-file PATH to select another file. Update logs include the preflight, selected DeviceId, fwupd commands, command output head and tail, post-install version verification, and the final state. Protect logs because they can contain dock identifiers.

Exit codes are:

  • 0: the command succeeded;
  • 1: no supported dock was detected;
  • 2: the command or an explicit firmware apply failed.

Firmware source

The updater uses Dell driver 389W0, which publishes the Linux CAB for the WD19 family. If Dell blocks its metadata page with HTTP 403, Dockwarden uses browser-compatible request headers and a pinned official CAB. It verifies the CAB SHA-256 before any firmware operation.

The candidate records package, embedded-controller, USB hub Gen1, USB hub Gen2, and MST versions. A live Dell candidate inherits those values only when its SHA-256 matches the pinned CAB. Missing or conflicting evidence gives version_check_unavailable; apply mode exits with code 2 and does not write.

The Windows .exe is never executed. The project does not bundle Dell firmware blobs.

Development

Build a development binary with Go 1.22 or newer:

GOCACHE=/tmp/dockwarden-go-cache go test ./...
GOCACHE=/tmp/dockwarden-go-cache go vet ./...
CGO_ENABLED=1 GOCACHE=/tmp/dockwarden-go-cache go build ./cmd/dockwarden

Run the release packaging checks without hardware:

sh -n tools/release/*.sh
sh tools/release/install_test.sh
sh tools/release/package_test.sh

The macOS fwupd port is built from the pinned Darwin branch commit. See the macOS build guide. The build runs upstream non-hardware tests and does not update a dock.

Tests use fake fwupd, HTTP, and command interfaces. They never flash a physical dock. See CONTRIBUTING.md for the development workflow.