This project is a feature-rich, single-zone HVAC thermostat built on the ESP32-C6 microcontroller. It is designed to be a robust and intelligent replacement for standard programmable thermostats, incorporating advanced safety, efficiency, and learning features typically found in high-end commercial products. All logic is processed locally on the device, ensuring privacy and offline functionality.
- 7-Day Programmable Schedule: Independent schedules for weekdays and weekends with up to 10 custom periods per day (e.g., Wake, Away, Home, Sleep).
- Multi-Mode Operation: Supports Heating, Cooling, Auto-Changeover, and Fan-Only modes.
- Fan Control: Includes
AUTO(runs with system),ON(always on), andCIRCULATE(runs periodically for a set time, e.g., 15 minutes every hour). - Unit Selection: Supports both Fahrenheit and Celsius for all temperature settings and readouts.
- Economizer (Free Cooling/Heating): Automatically uses the fresh air intake instead of the furnace or A/C when outdoor temperature is favorable, significantly reducing energy consumption.
- Time to Temperature (Smart Recovery): Proactively learns the thermal performance of your home and starts heating or cooling before a scheduled change to reach the target temperature precisely at the scheduled time.
- Seasonal Performance Learning: The smart recovery feature learns and stores separate performance data for all four seasons, allowing it to make more accurate predictions as outdoor conditions change throughout the year.
- Local Learning Framework: A system for logging manual user adjustments to the onboard filesystem (SPIFFS/LittleFS), enabling future implementation of algorithms that can automatically adjust the schedule based on user behavior.
- Cycle Protection: Enforces configurable minimum run times and minimum off times for both heating and cooling equipment to prevent short-cycling and protect the HVAC compressor and components.
- Maximum Run Time Protection: A critical safety feature that shuts down a heating or cooling cycle if it runs for an excessively long time (e.g., 90 minutes), preventing runaway operation due to a fault or open window.
- System Lockout: If the maximum run time is triggered multiple times within a set period, the thermostat will enter a full system lockout to protect the HVAC from major damage, requiring a manual reset.
- Sensor Fault Detection: Validates that sensor readings are within a plausible range. If a fault is detected, the system enters a safe fault state, shutting down all relays.
- Hardware Watchdog Timer: Utilizes the ESP32's built-in watchdog to automatically reboot the device if the main code ever freezes, ensuring the system never gets stuck with a relay on.
- Power-On Delay: Waits for a few seconds after booting before starting any HVAC operations to protect against power surges.
- Persistent Storage (NVS): All user settings, including the full schedule and learned performance data, are saved to the ESP32's Non-Volatile Storage, ensuring all configurations are retained through power outages.
The project is organized into a clean, modular, multi-file structure to separate concerns and improve maintainability.
- Role: The main application entry point and coordinator.
- Responsibilities:
- Initializes all hardware and software modules (
Serial, NVS, Watchdog, Filesystem). - Loads settings from NVS on boot.
- Runs the main
loop(), which orchestrates calls to all other modules. - Handles top-level logic like sensor fault detection and smart recovery calculations.
- Contains the hardware abstraction layer (e.g.,
readRelay,writeRelay) to facilitate testing.
- Initializes all hardware and software modules (
- Role: A centralized header for all system-wide configurations.
- Responsibilities:
- Defines all user-configurable settings (default temperature unit, cycle times, etc.).
- Contains all hardware pin assignments and data structures like
ScheduleandHvacPerformance. - Holds all
enumdefinitions for modes likeSystemModeandFanMode.
- Role: The core HVAC control engine.
- Responsibilities:
- Contains the primary
controlTemperature,controlFan, andcontrolHumidityfunctions. - Implements all the rules-based logic for when to turn relays on or off.
- Manages all cycle protection timers and the safety lockout logic.
- Contains the logic for measuring and learning HVAC performance data after each cycle.
- Contains the primary
- Role: The module for on-device machine learning.
- Responsibilities:
- Initializes the SPIFFS/LittleFS filesystem.
- Provides the
log_manual_adjustment()function to write user overrides to a log file. - Contains the placeholder
analyze_and_learn_if_needed()function.
- Role: A self-contained suite for unit and logic testing.
- Responsibilities:
- Contains the
runTests()function, which is called fromsetup()on boot. - Includes specific test functions for every major feature.
- Uses a mocking framework to simulate time, sensor inputs, and relay states.
- Contains the
- IDE: This project is designed to be built with an IDE that supports the ESP-IDF framework, such as VS Code with the PlatformIO extension.
- File Structure: In PlatformIO, place
.hfiles in theincludedirectory and.cppfiles in thesrcdirectory. - Libraries: No external libraries are required beyond what is included with the standard ESP-IDF.
- Configuration: Modify the settings in
include/config.hto match your HVAC system. - Build & Upload: Use PlatformIO to build and upload the project to your ESP32-C6 board.
- Monitor: Open the Serial Monitor at